The FT Series is a premium line of Front Terminal VRLA batteries designed specifically for the telecommunications and data center industries. With its unique slim-line architecture and front-access terminals, this 12V series provides high energy density while dramatically simplifying installation and maintenance in space-constrained environments. By combining 99.994% high-purity lead with advanced patented alloys and central degassing technology, the FT series offers a reliable 12-year energy backbone for 19-inch and 23-inch rack systems, ensuring seamless operation for critical network infrastructure.
Key Features:
-
Optimized Rack Integration: The narrow profile and front-facing terminals allow for easy access and compact stacking within standard 19/23-inch cabinets, making it the industry standard for telecom power.
-
Precision Manufacturing: Adopts a high-temperature and high-humidity curing process combined with an ear-hanging plate design, ensuring perfect batch consistency in capacity and life.
-
Advanced Safety & Ventilation: The integrated central gas collection system safely directs emissions, while the hidden independent safety valve prevents blockages and maintains ideal internal pressure.
-
Superior Material Engineering: Features high-purity electrolytic lead and a patented alloy formula to resist grid corrosion, ensuring the battery maintains performance throughout its decade-long lifespan.
-
Maintenance-Free Reliability: Fully sealed and maintenance-free design allows for flexible placement and safe operation in proximity to sensitive electronic equipment.
Application Scenarios:
-
Telecommunications Hubs: Ideal for 48V DC power systems in central offices, remote switching sites, and cellular base stations.
-
Data Centers & IT Racks: Provides compact, high-density backup power for server rooms and cloud computing facilities.
-
Uninterruptible Power Supplies (UPS): Reliable energy storage for rack-mounted UPS systems in commercial and industrial settings.
-
Renewable Energy Microgrids: Suitable for solar and wind energy storage in localized power cabinets.
-
Railway & Communication Signals: Ensures uninterrupted power for critical transportation and signaling networks.
Product parameters:
| Battery model | Rated voltage (V) | Rated capacity C10(Ah) | Battery size | Terminal options | Terminal location | |||
| Length/mm | Width/mm | Height/mm | Total height/mm | |||||
| FT12-55 | 12 | 55 | 291 | 106 | 230 | 230 | F11(M6) | E |
| FT12-55A | 12 | 55 | 291 | 106 | 230 | 230 | F11(M6) | E |
| FT12-90 | 12 | 90 | 562 | 114 | 188 | 188 | F6(M8) | E |
| FT12-90A | 12 | 90 | 562 | 114 | 188 | 188 | F6(M8) | E |
| FT12-100 | 12 | 100 | 508 | 110 | 236 | 236 | F14(M8) | E |
| FT12-100A | 12 | 100 | 508 | 110 | 236 | 236 | F14(M8) | E |
| FT12-100S | 12 | 100 | 410 | 109 | 285 | 293 | F14(M8) | E |
| FT12-100SA | 12 | 100 | 410 | 109 | 285 | 293 | F14(M8) | E |
| FT12-105 | 12 | 105 | 508 | 110 | 236 | 236 | F14(M8)/F8(M6) | E |
| FT12-105A | 12 | 105 | 508 | 110 | 236 | 236 | F14(M8)/F8(M6) | E |
| FT12-110 | 12 | 110 | 410 | 109 | 285 | 293 | F14(M8) | E |
| FT12-110A | 12 | 110 | 410 | 109 | 285 | 293 | F14(M8) | E |
| FT12-150 | 12 | 150 | 565 | 110 | 288 | 288 | F14(M8) | E |
| FT12-150A | 12 | 150 | 565 | 110 | 288 | 288 | F14(M8) | E |
| FT12-160 | 12 | 160 | 565 | 110 | 288 | 288 | F14(M8) | E |
| FT12-170 | 12 | 170 | 560 | 125 | 316 | 316 | F14(M8) | E |
| FT12-180 | 12 | 180 | 560 | 125 | 316 | 316 | F14(M8) | E |
| FT12-180A | 12 | 180 | 560 | 125 | 316 | 316 | F14(M8) | E |
| FT12-185 | 12 | 185 | 560 | 125 | 316 | 316 | F14(M8) | E |
| FT12-200 | 12 | 200 | 560 | 125 | 316 | 316 | F14(M8) | E |
| FT12-200A | 12 | 200 | 560 | 125 | 316 | 316 | F14(M8) | E |
| Battery model | Rated voltage (V) | Rated capacity C20(Ah) | Battery size | Terminal options | Terminal location | |||
| Length/mm | Width/mm | Height/mm | Total height/mm | |||||
| FT12-55D | 12 | 55 | 291 | 106 | 230 | 230 | F11(M6) | E |
| FT12-90D | 12 | 90 | 562 | 114 | 188 | 188 | F6(M8) | E |
| FT12-100D | 12 | 100 | 508 | 110 | 236 | 236 | F14(M8) | E |
| FT12-100SD | 12 | 100 | 410 | 109 | 285 | 293 | F14(M8) | E |
| FT12-105D | 12 | 105 | 508 | 110 | 236 | 236 | F14(M8)/F8(M6) | E |
| FT12-110D | 12 | 110 | 410 | 109 | 285 | 293 | F14(M8) | E |
| FT12-150D | 12 | 150 | 565 | 110 | 288 | 288 | F14(M8) | E |
| FT12-160D | 12 | 160 | 565 | 110 | 288 | 288 | F14(M8) | E |
| FT12-180D | 12 | 180 | 560 | 125 | 316 | 316 | F14(M8) | E |
| FT12-185D | 12 | 185 | 560 | 125 | 316 | 316 | F14(M8) | E |
| FT12-200D | 12 | 200 | 560 | 125 | 316 | 316 | F14(M8) | E |
| Battery model | Rated voltage (V) | Rated capacity C20(Ah) | Battery size | Terminal options | Terminal location | |||
| Length/mm | Width/mm | Height/mm | Total height/mm | |||||
| FT12-55G | 12 | 55 | 291 | 106 | 230 | 230 | F11(M6) | E |
| FT12-90G | 12 | 90 | 562 | 114 | 188 | 188 | F6(M8) | E |
| FT12-100G | 12 | 100 | 508 | 110 | 236 | 236 | F14(M8) | E |
| FT12-105G | 12 | 105 | 508 | 110 | 236 | 236 | F17(M8)/F8(M6) | E |
| FT12-110G | 12 | 110 | 410 | 109 | 285 | 293 | F14(M8) | E |
| FT12-150G | 12 | 150 | 565 | 110 | 288 | 288 | F14(M8) | E |
| FT12-160G | 12 | 160 | 565 | 110 | 288 | 288 | F14(M8) | E |
| FT12-180G | 12 | 180 | 560 | 125 | 316 | 316 | F14(M8) | E |


Reviews
There are no reviews yet.